| Type: |
E30-16-1×6.3 |
| Exhaust arrangement: |
Axial |
| Flow arrangement: |
Straight Flow |
| Turbine design conditions: |
Main steam flow: 134 kg/s; |
| |
Main steam pressure: 90 bar; |
| |
Main steam temperature: 520°C |
| |
Admission steam flow: 18 kg/s; |
| |
Admission steam pressure: 8.23 bar; |
| |
Admission steam temperature: 230°C |
| |
Maximum allowed main steam pressure: 94.5 bar |
| |
Maximum allowed main steam temperature: 520°C |
| |
Maximum allowed main steam flow: 140.7 kg/s |
| |
Maximum allowed mass flow at end-stage: 160 kg/s |
| |
Maximum allowed back pressure (trip value): 0.5 bar |
| |
Maximum efficiency: 10806 kj/kWh at 0.115 bar condenser back pressure (air cooled) |
| |
|